论文标题

机械变形对低温电流比较器的同轴屏蔽性能的影响

Influence of mechanical deformations on the performance of a coaxial shield for a cryogenic current comparator

论文作者

Marsic, Nicolas, Müller, Wolfgang F. O., Tympel, Volker, Stöhlker, Thomas, Stapelfeld, Max, Schmidl, Frank, Schmelz, Matthias, Zakosarenko, Vyacheslav, Stolz, Ronny, Haider, David, Sieber, Thomas, Schwickert, Marcus, De Gersem, Herbert

论文摘要

本文研究了机械变形对同轴型低温电流比较器(CCC)的性能的影响。随着CCC的大小增加(例如,当用作涉及较大直径较大的梁线的颗粒加速器设备中的诊断设备时),这种变形可能成为一个问题。除静态变形外,本文还讨论了机械振动对CCC性能的影响。

This paper studies the impact of mechanical deformations on the performance of a coaxial-type cryogenic current comparator (CCC). Such deformations may become a concern as the size of the CCC increases (e.g. when used as a diagnostic device in a particle accelerator facility involving beamlines with a large diameter). In addition to static deformations, this paper also discusses the effect of mechanical vibrations on the CCC performance.