论文标题
APERTIF成像调查数据的首版
First release of Apertif imaging survey data
论文作者
论文摘要
(删节的)Apertif是一个用于WSRT的相分阵列进料系统,可为300 MHz带宽提供40张瞬时光束。一项专门的调查计划于2019年7月1日开始,最后观察到2022年2月28日。我们描述了从调查运营第一年到2020年6月30日的数据产品的发布。我们专注于定义处理后数据产品的质量控制指标。 APERTIF成像管道,Apercal,自动产生非主要光束校正的连续图像,极化图像和立方体,以及未清洁的光谱线和肮脏的光束立方体,用于APERTIF成像观察的每个光束。对于此版本,在观察过程中以逐梁的基础考虑处理后的数据产品。我们通过使用识别残留图像中高斯噪声偏差的指标来验证连续图像。如果连续图像通过验证,我们为给定梁释放所有处理的数据产品。我们将进一步的验证应用于极化和线数据产品。我们从调查观察的第一年释放所有原始观察数据,总共有221个观测值为160个独立的目标场,覆盖了大约一千平方的天空。图像和立方体以每光束释放,并释放3374梁。连续图像中的中值噪声为41.4 UJY/BM,在Stokes V极化图像中,中位噪声略低于36.9 UJY/BM。中值角分辨率为11.6英寸/sin(dec)。所有线立方体的中值噪声,光谱分辨率为36.6 kHz,为1.6 mjy/bm,对应于3-sigma hi柱密度的敏感性1.8 x 10^20^20^20^20^20^20原子cm^-2在20 km/s的均值中,用于单个轴/s(用于均值的均值),并提供24“ x 24” x 15”。光束使用虚拟观测界界面可访问数据。
(Abridged) Apertif is a phased-array feed system for WSRT, providing forty instantaneous beams over 300 MHz of bandwidth. A dedicated survey program started on 1 July 2019, with the last observations taken on 28 February 2022. We describe the release of data products from the first year of survey operations, through 30 June 2020. We focus on defining quality control metrics for the processed data products. The Apertif imaging pipeline, Apercal, automatically produces non-primary beam corrected continuum images, polarization images and cubes, and uncleaned spectral line and dirty beam cubes for each beam of an Apertif imaging observation. For this release, processed data products are considered on a beam-by-beam basis within an observation. We validate the continuum images by using metrics that identify deviations from Gaussian noise in the residual images. If the continuum image passes validation, we release all processed data products for a given beam. We apply further validation to the polarization and line data products. We release all raw observational data from the first year of survey observations, for a total of 221 observations of 160 independent target fields, covering approximately one thousand square degrees of sky. Images and cubes are released on a per beam basis, and 3374 beams are released. The median noise in the continuum images is 41.4 uJy/bm, with a slightly lower median noise of 36.9 uJy/bm in the Stokes V polarization image. The median angular resolution is 11.6"/sin(Dec). The median noise for all line cubes, with a spectral resolution of 36.6 kHz, is 1.6 mJy/bm, corresponding to a 3-sigma HI column density sensitivity of 1.8 x 10^20 atoms cm^-2 over 20 km/s (for a median angular resolution of 24" x 15"). We also provide primary beam images for each individual Apertif compound beam. The data are made accessible using a Virtual Observatory interface.