论文标题
SXFEL-UF的多个起伏线操作的梁分配系统的设计和调试
Design and Commissioning of A Beam Distribution System for Multiple Undulator Line Operation of the SXFEL-UF
论文作者
论文摘要
作为提高X射线无电子激光器设施的效率和可用性的重要衡量标准,在最近的XFEL设施中,由光束分配系统实现的多个未开关线的同时操作已成为标准配置。在上海,SXFEL-UF是中国的第一个软X射线激光用户设施,最近完成了建设并开始进行调试。来自LINAC的电子束通过具有6°偏转线的光束分配系统交替分布在两个平行的波动孔线之间。光束分配系统旨在保持梁的性能,例如低升空,高峰值电荷和小束长度。梁集体效应,例如色散,相干同步辐射和微束式不稳定性,应得到很好的抑制,以确保光束质量。在这项工作中,描述了光束分配系统的详细物理设计,并报告了最近的调试结果。
As an important measure of improving the efficiency and usability of X-ray free electron laser facilities, simultaneous operation of multiple undulator lines realized by a beam distribution system has become a standard configuration in the recent built XFEL facilities. In Shanghai, SXFEL-UF, the first soft X-ray free electron laser user facility in China, has finished construction and started commissioning recently. Electron beam from linac is alternately distributed between the two parallel undulator beam lines by a beam distribution system with a 6° deflection line. The beam distribution system is designed to keep the beam properties like low emittance, high peak charge and small bunch length from being spoiled. Beam collective effects such as the dispersion, coherent synchrotron radiation and micro-bunching instability should be well suppressed to guarantee the beam quality. In this work, the detailed physics design of the beam distribution system is described and the recent commissioning result is reported.